Industrial Direct Fired Vertical - Single(FAV)
- Air Volume: 5,000 – 46,000 cfm
- Maximum SP: 5" wg. at standard air density
-
Casing
- internal tubular frame
- double wall doors
- rear doors on Model22 & larger
- G-90 galvanized steel
- weatherproof construction
- hinged service doors with flush-mount latches
- six discharge options
-
Blower
- FC-DWDI centrifugal blower assembly
- v-belt drive
- 100,000 hour greasable bearings (Model 18-236)
- permanent lubricated bearings (Model 10-15)
- solid steel shaft
- split shafts with couplings on twin units
-
Burner
- wide-range, high capacity line burner
- up to 30:1 turndown ratio
- electric-pilot spark ignition
- Burner Economizer Thermostat
- Burner-Observation Port
-
Manifold Controls Vestibule
- weatherproof enclosure
- easy-access to manifold and controls
- manifold built to required codes
-
Electrical Controls Vestibule
- weatherproof enclosure
- easy-access to manifold and controls
- exhaust-interlock terminals
- terminal strip for quick service check
- burner and blower service switches
- Gas Connection
-
Motor
- standard, high E, open-drip proof with adjustable motor mount
- v-belt drive
- adjustable drive up to and including 25 HP
- starter with burner interlock
-
Lifting Eyes
- standard heavy-duty lifting lugs
-
Controls
- electronic flame safety controls
- ignition transformer
- airflow proving control
- high-temperature safety controls
- burner and blower service switches
-
Remote Control Panel
- Summer-Off-Winter switch
- "Blower on" light
- "Burner on" light
- Other lights available
Adjustable drives: fixed-pitched sheaves are standard on motors 30hp and larger. An adjustable-pitch motor sheave is provided in lieu of the standard fixed-pitch sheave.
Casing insulation: adds 1", 1.5 lb density insulation, that is glued and pinned to inner surface of unit's walls and ceiling, casing liners are standard with this option.
Casing liners with insulation: prevents insulation fibers from being drawn into air stream and discharged into conditioned space, and prevents physical abuse and moisture damage to insulation. Made of galvanized steel.
Extended grease lines: lubrication lines from blower bearings to a common point on the unit's exterior. Units with permanently lubricated bearings to be changed to pillow block-type.
Painted casings: one coat of beige air-dried enamel over a vinyl wash primer.
Pillow-block bearings, 100,000 hr: standard on all units ordered with an industrial blower, and are rated at 100,000 to 200,000 hours; available on smaller units with standard, permanently lubricated ball bearings.
Discharge damper, two-position motor and interlock: motor-operated parallel blade damper that prevents warm air from escaping the building through the unit. The motor-damper end switch energizes the starter circuit when the damper is in the full-open position, and returns to a closed position during shutdown.
Discharge louvers with air diffuser: discharges air in four directions with vertical and horizontal blades, and is field-installed. The blades can be manually adjusted to set direction of airflow.
Filter section: removable, hinged access door, with a 2-inch washable, aluminum-mesh filter, or a 2-inch pleated filter. Also available with 1-inch, 1.5 lb density insulation.
Inlet screen: prevents material from entering unit. A 1-inch mesh screen fastens to unit's fresh-air intake.
Return-air filter, 80/20 units: 1-inch or 2-inch deep, aluminum mesh, or 2-inch deep, 30% efficient, pleated type; v-bank, filter section shipped loose for field mounting to the return-air connection.
The FAV Model has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. and Canadian products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance.
Model FAV is ETL Listed under file number 3013648-002 and complies with ANSI Z83.4-Second Edition and CSA 3.7-2006 Standards.
Additional Information
Specifications
- FAV 18 with 18" burnerVertical Industrial Heater with a 18" burner and a 18" blower.
- FAV 18 with 24" burnerVertical Industrial Heater with a 24" burner and a 18" blower.
- FAV 18 with 30" burnerVertical Industrial Heater with a 30" burner and a 18" blower.
- FAV 18 with 36" burnerVertical Industrial Heater with a 36" burner and a 18" blower.
- FAV 20 with 18" burnerVertical Industrial Heater with a 18" burner and a 20" blower.
- FAV 20 with 24" burnerVertical Industrial Heater with a 24" burner and a 20" blower.
- FAV 20 with 30" burnerVertical Industrial Heater with a 30" burner and a 20" blower.
- FAV 20 with 36" burnerVertical Industrial Heater with a 36" burner and a 20" blower.
- FAV 20 with 42" burnerVertical Industrial Heater with a 42" burner and a 20" blower.
- FAV 25 with 36" burnerVertical Industrial Heater with 36" of burner and 25" blower.
- FAV 25 with 48" burnerVertical Industrial Heater with 48" of burner and 25" blower.
- FAV 25 with 60" burnerVertical Industrial Heater with 60" of burner and 25" blower.
- FAV 25 with 72" burnerVertical Industrial Heater with 72" of burner and 25" blower.
- FAV 25 with 84" burnerVertical Industrial Heater with 84" of burner and 25" blower.
- FAV 30 with 60" burnerVertical industrial heater with 60" of burner and 30" blower.
- FAV 30 with 72" burnerVertical industrial heater with 72" of burner and 30" blower.
- FAV 30 with 84" burnerVertical industrial heater with 84" of burner and 30" blower.
- FAV 36 with 72" burnerVertical industrial heater with 72" of burner and 36" blower.
- FAV 36 with 84" burnerVertical industrial heater with 84" of burner and 36" blower.
- FAV 36 with 96" burnerVertical industrial heater with 96" of burner and 36" blower.
- FAV 36 with 108" burnerVertical industrial heater with 108" of burner and 36" blower.
- FAV 36 with 120" burnerVertical industrial heater with 120" of burner and 36" blower.
- FAV 36 with 132" burnerVertical industrial heater with 132" of burner and 36" blower.
- FAV 36 with 144" burnerVertical industrial heater with 144" of burner and 36" blower.
- FAV 36 with 162" burnerVertical industrial heater with 162" of burner and 36" blower.
- FAV 36 with 174" burnerVertical industrial heater with 174" of burner and 36" blower.