Low CFM Direct Fired Heater(F76)
The Direct Gas Fired Make-Up Air package is designed to deliver tempered make-up air for installations requiring frequent air changes. Units are designed for natural and propane gas applications, and for indoor or outdoor installation.
- Air Volume: 600 – 1,400 cfm
- Maximum SP: 1.12" wg. at standard air density
- G90 galvanized construction.
- Easy access doors.
- Pre-wired, pre-piped controls.
- Horizontal or down discharge.
- Adjustable drive sheaves.
- Fully insulated casing.
- Stainless steel burner with aluminum casting.
- 120 volt control transformer with single point electrical connection.
- Redundant gas valves.
- Intermittent spark pilot with timed safety lockout.
- Electronic flame modulation.
- High temperature limit switch.
- Airflow proving switch.
- Economizer inlet thermostat.
- Motor starter.
- Disconnect switch.
- Burner observation port.
- Propane Fuel Application.
- Room Override Thermostat.
- Motorized Intake Damper.
- Remote control panel including summer/winter switch and operating lights.
- Freeze Stat with Bypass Timer.
- Room Modulating Thermostat.
- High Gas Pressure Regulator.
- Convenience Outlet.
- Screen Intake.
- Auxiliary Starters.
- Inlet Gas Pressure Gauge.
- Indoor Hanging Cradle.
- VAV Packages.
- Roof Curbs.
- Extra Set of V-Belts.
- DDC Control capability for BACnet MS/TP, LonWorks, Johnson N2, and Modbus Protocol.
![ETL Listed](/assets/img/icons/certifications/etl-listed-canada-us.png)
The F76 Model has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. and Canadian products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance.
Model F76 is ETL Listed under file number 103371695COL-001 and complies with ANSI Z83.4-Second Edition and CSA 3.7-2006 Standards.
Manuals
Drawings
- Indoor
-
Outdoor
- Down Discharge with Filter and Screen Intake
- Side Discharge with Filter and Screen Intake
- Down Discharge with Filter, Trunk-line, and Screen Intake
- Side Discharge with Filter, Trunk-line, and Screen Intake
- Side Discharge with LPD Evap and Intake Hood
- Down Discharge with LPD Evap and Intake Hood
- Side Discharge with LPD Evap and Screen Intake
- Down Discharge with LPD Evap and Screen Intake
- Rooftop Package
- F76Low CFM Direct Fired Heater. Belt Drive.
- F76DLow CFM Direct Fired Heater. Direct Drive.